Commercial Cooking Without a Hood

Commercial Cooking Without a Hood: The Equipment You Need Instead
Last updated: Jan 24, 2026

Ventless equipment solutions for commercial kitchens where traditional exhaust hoods aren't feasible

Commercial cooking without a traditional exhaust hood is one of the most common challenges facing new restaurant operators, ghost kitchen startups, and food truck businesses. Traditional hood installation costs $10,000-$25,000 and requires significant infrastructure; ductwork through ceilings, rooftop penetrations, and make-up air systems. For many locations, installation simply isn't possible.

The good news: ventless cooking technology has advanced significantly. Today's ventless equipment uses built-in filtration systems (catalytic converters, charcoal filters, and HEPA filters) to capture grease, smoke, and odors without external venting. These solutions are code-compliant in most jurisdictions when properly specified.

Important: Health codes vary by location. Before purchasing any equipment, consult your local health department and fire marshal to confirm compliance requirements for your specific operation.

Why Traditional Hoods Aren't Always Possible

Restaurant operators face several common obstacles:

Challenge:Details:
High installation cost$10,000-$25,000+ for hood, ductwork, rooftop unit, and make-up air system
Building constraintsStrip malls, basements, and multi-story buildings often prohibit roof penetrations
Historic buildingsPreservation requirements may prevent structural modifications
Lease restrictionsMany landlords won't permit permanent ventilation installations
Space limitationsHoods must extend 6" beyond equipment on all sides - some kitchens can't accommodate
Shared spacesGhost kitchens and commissary kitchens may not allow tenant modifications

If you're facing any of these constraints, the following solutions can help you operate legally without traditional exhaust infrastructure.

Traditional Hood System Cost Breakdown

Understanding where the $10,000-$25,000+ goes helps explain why operators seek alternatives:

Component:Typical Cost:
Hood canopy (Type I, 8-10 ft)$2,000-$6,000
Exhaust fan system$1,500-$4,000
Ductwork installation$2,000-$8,000
Make-up air unit$3,000-$10,000
Fire suppression system$2,000-$5,000
Permits & inspections$500-$2,000
Total installed cost$11,000-$35,000+

Why Make-Up Air Adds Complexity

Traditional exhaust hoods create negative pressure by removing air from the kitchen. Per IMC 508.1, mechanical make-up air systems must:

  • Replace 80-90% of exhausted air volume
  • Start and operate simultaneously with the exhaust system
  • Be properly balanced to avoid negative pressure issues

Without adequate make-up air:

  • Doors become difficult to open/close
  • Hood capture efficiency decreases significantly
  • Gas-fired appliances may backdraft dangerously
  • HVAC systems work harder, increasing energy costs

Ventless advantage: Self-contained filtration recirculates cleaned air back into the kitchen, eliminating make-up air requirements entirely.

Equipment Hood Requirements Quick Reference

Understanding which equipment requires ventilation helps you plan a compliant kitchen. Below are general guidelines based on IMC (International Mechanical Code) standards; always verify with your local authority having jurisdiction (AHJ).

Equipment That Typically Requires a Type I Hood

Type I hoods remove grease, smoke, and heat. Per IMC Section 507, they're required for equipment producing grease-laden vapors.

Equipment:Why It Needs Type I:Shop Link:
Commercial RangesOpen flames, grease splatter, high BTU outputGas Ranges | Electric Ranges
Deep FryersHot oil produces grease-laden vaporsGas Fryers | Electric Fryers
CharbroilersOpen flame, high grease, smoke productionShop Charbroilers
GriddlesGrease accumulation, high surface temperaturesGas Griddles | Electric Griddles
Convection OvensStandard models produce heat and some grease vaporsShop Convection Ovens
Pizza OvensHigh temperatures, grease from toppingsDeck | Conveyor
Rotisserie OvensGrease drip from rotating proteinsShop Rotisserie Ovens
Smoker OvensSmoke and grease productionShop Smoker Ovens
Wok RangesHigh BTU, open flame, grease splatterShop Wok Ranges
Tilt Skillets & Braising PansLarge-volume cooking with greaseShop Tilt Skillets
BroilersHigh heat, grease from proteinsSalamanders | Upright

Type I Hood Placement (per IMC):

  • 18" minimum above cooking surface without exposed flame
  • 24" minimum above surfaces with exposed flame/burners
  • 42" minimum above charcoal/charbroiler appliances
  • Maximum 4 feet (48") above cooking surface

Fire Suppression Requirement: Per IBC/IFC, all Type I hoods require an approved automatic fire suppression system; normally around an additional $2,000-$5,000 for traditional installations. Some ventless hoods include integrated suppression; verify requirements with your fire marshal.

Equipment That Typically Requires a Type II Hood

Type II hoods (condensate hoods) remove steam, vapor, and moisture; but not grease. They're used where heat and moisture are present without significant grease production.

Equipment:Why It Needs Type II:Shop Link:
Commercial DishwashersHigh steam output during cyclesShop Dishwashers
Steam KettlesLarge-volume steam releaseShop Steam Kettles
Commercial SteamersContinuous steam during cookingShop Steamers
Pasta CookersBoiling water produces significant steamShop Pasta Cookers
Combi Ovens (steam mode)Steam cooking produces moistureShop Combi Ovens

Note: Some Type II equipment may operate without a hood if designed as "ventless" (e.g., ventless dishwashers that recapture steam).

Equipment That Typically Does NOT Require a Hood

The following equipment generally operates below grease/heat thresholds or uses self-contained ventilation. However, local codes vary; always confirm with your AHJ.

Equipment:Why No Hood Typically Required:Shop Link:
Commercial MicrowavesEnclosed cooking, no grease-laden vaporsShop Microwaves
Commercial ToastersLow heat, minimal grease productionShop Toasters
Rice CookersEnclosed steam, low temperatureShop Rice Cookers
Holding CabinetsHolding temperature only, no active cookingShop Holding Cabinets
Heat Lamps & Strip WarmersRadiant heat, no combustion or greaseShop Heat Lamps
Steam TablesHolding temperature, water-based heatShop Steam Tables
Hot Dog Roller GrillsLow-temperature, enclosed cookingShop Hot Dog Grills
Coffee EquipmentNo grease, steam vented internallyShop Coffee Equipment
Air Fryers (ventless models)Self-contained filtration, no oilShop Air Fryers
Induction CookersNo combustion; many countertop models exemptShop Induction
Panini & Sandwich GrillsEnclosed cooking surface, low greaseShop Panini Grills
Waffle MakersEnclosed, low-temperature cookingShop Waffle Makers
Crepe MachinesLow temperature, minimal greaseShop Crepe Machines
Sous Vide / Immersion CirculatorsWater bath, no vaporsShop Sous Vide
Rapid Cook Ovens (ventless)Built-in catalytic convertersShop Rapid Cook Ovens
Drawer WarmersHolding only, no active cookingShop Drawer Warmers

Important Exception (UL 710B): Per IMC, electric cooking appliances tested to UL 710B that produce ≤5 mg/m³ of grease at 500 CFM do NOT require a Type I hood. Many ventless and rapid cook ovens meet this standard; check the equipment specification sheet.

Solution 1: Ventless Cooking Equipment

Ventless cooking equipment has built-in exhaust filtration, allowing operation without external venting. These units capture grease and smoke internally, then recirculate clean air back into the kitchen.

Rapid Cook Ovens

Rapid cook ovens (also called accelerated cooking ovens or speed ovens) combine convection, microwave, and sometimes impingement technology to cook food 10-15x faster than conventional ovens. Many models are available in ventless configurations.

Best for: High-volume quick-service, convenience stores, cafes, ghost kitchens Typical cost: $8,000-$25,000 Cooking capacity: 10-50 items per hour depending on model

Key advantages:

  • No hood required (self-contained filtration)
  • Compact footprint (fits on countertops)
  • Versatile; bakes, toasts, reheats, cooks from frozen
  • Energy efficient compared to traditional cooking lines

Considerations:

  • Higher upfront cost than conventional equipment
  • Filter maintenance required (typically monthly)
  • Limited to smaller batch sizes

Ventless Convection Ovens

Standard convection ovens with integrated ventless hood systems provide traditional baking and roasting capabilities without external exhaust requirements.

Best for: Bakeries, cafes, restaurants needing roasting/baking capacity Typical cost: $3,000-$15,000 (oven) + $2,000-$8,000 (ventless hood attachment) Cooking capacity: Full sheet pans, multiple racks

Solution 2: Ventless Hood Systems

If you need to operate traditional cooking equipment (fryers, griddles, charbroilers) without building-mounted exhaust, ventless hood systems provide a self-contained alternative. These units mount above your equipment and use multi-stage filtration to capture grease and smoke.

How Ventless Hoods Work

Ventless hood systems typically use a three-stage filtration process:

  1. Grease filters - Baffle or mesh filters capture airborne grease particles
  2. Charcoal/carbon filters - Absorb smoke and odors
  3. HEPA or catalytic filters - Final stage removes remaining particulates

The filtered air is then recirculated into the kitchen rather than exhausted outside.

Ventless Hood Options

Type:Brands Available:Best For:
Countertop ventless hoodsUNOX, EquipexCombi ovens, panini grills, small griddles
Universal ventless hoodsMoffat, ElectroluxMedium-duty professional kitchen equipment
Fryer-specific ventless hoodsGilesDeep fryers, high-grease cooking operations
Full-size universal hoodsWellsHeavy-duty equipment, large cook lines

Important considerations:

  • Match hood size to your equipment (hood must cover the entire cooking surface)
  • Factor in ongoing filter replacement costs ($200-$500 annually)
  • Ensure adequate clearance above equipment (typically 18-24 inches minimum)
  • Verify UL/NSF certification for your jurisdiction

Solution 3: Warming and Holding Equipment

For operations focused on reheating pre-cooked food rather than raw cooking, warming equipment often operates below the heat thresholds that trigger hood requirements. This approach is common for:

  • Food trucks warming commissary-prepared items
  • Ghost kitchens reheating bulk-prepared food
  • Catering operations holding pre-cooked dishes

Equipment that may not require hoods:

  • Heat lamps and strip warmers
  • Holding cabinets and hot boxes
  • Steam tables and bain-maries
  • Soup warmers and rethermalizers

Typical wattage: Under 2,000 watts (check local codes - thresholds vary)

Important: Even low-heat equipment may require ventilation in some jurisdictions. Always verify with your local health department.

Solution Comparison

Solution:Best For:Cost Range:Cooking Capability:Maintenance:
Rapid cook ovensHigh-speed cooking, versatile menus$8,000-$25,000Full cooking from rawMonthly filter changes
Ventless convection ovensBaking, roasting, traditional cooking$5,000-$23,000Full baking/roastingMonthly filter changes
Ventless hood + equipmentHeavy-duty cooking (frying, grilling)$6,500-$30,000+Full commercial cookingFilter replacement 2-4x/year
Warming equipment onlyReheating, holding pre-cooked food$500-$3,000Reheating onlyMinimal

Compliance Checklist

Before finalizing your equipment selection, work through this checklist with your local authorities:

Questions for Your Health Department

  • What cooking equipment is permitted without traditional exhaust in your jurisdiction?
  • Are ventless hoods accepted as equivalent to ducted systems?
  • What wattage/BTU thresholds trigger hood requirements?
  • Is a fire suppression system required for your equipment configuration?
  • What certifications (UL, NSF, ETL) are required for approval?

Questions for Your Fire Marshal

  • What fire suppression requirements apply to your equipment?
  • Are there clearance requirements between equipment and combustibles?
  • Is a Type I or Type II hood classification required?
  • What documentation is needed for permit approval?

Equipment Specifications to Have Ready

  • Manufacturer and model number
  • Voltage/wattage (electric) or BTU rating (gas)
  • Whether equipment has built-in exhaust/filtration
  • Equipment dimensions and required clearances
  • UL/NSF listing numbers

Frequently Asked Questions

Q:

Can I operate a commercial kitchen without any exhaust hood?

A:

Yes, in most jurisdictions, if you use only ventless cooking equipment with built-in filtration or limit operations to warming/holding equipment below local heat thresholds. However, requirements vary significantly by location. Always verify with your local health department before purchasing equipment.

Q:

How much does ventless cooking equipment cost compared to traditional setups?

A:

Ventless equipment typically costs $8,000-$25,000 upfront, while a traditional hood system runs $10,000-$25,000 for installation alone. When you factor in ductwork, rooftop units, and make-up air systems, traditional ventilation can exceed $30,000-$50,000. Ventless solutions often have lower total cost of ownership despite higher equipment prices.

Q:

Are ventless hoods accepted by health departments?

A:

Most jurisdictions accept UL-listed ventless hood systems as equivalent to traditional exhaust when properly matched to cooking equipment. However, some locations have specific restrictions or additional requirements. Approval is not automatic. Submit equipment specifications to your health department for pre-approval before purchasing.

Q:

What ongoing maintenance do ventless systems require?

A:

Ventless equipment requires regular filter replacement; typically monthly for grease filters and every 3-6 months for charcoal/carbon filters. Annual filter costs range from $200-$500 depending on equipment type and usage volume. Neglecting filter maintenance reduces efficiency and can void warranties.

Q:

Can I use a deep fryer without a hood?

A:

Deep fryers typically require Type I hood ventilation due to high grease production. However, full-size ventless hood systems (like Wells models) are designed to handle fryer exhaust when properly sized. Electric fryers produce less exhaust than gas fryers and may be easier to approve in ventless configurations.

Q:

What about gas equipment, can that be ventless?

A:

Gas cooking equipment is more challenging for ventless applications because it produces combustion byproducts in addition to cooking exhaust. Most ventless solutions work best with electric equipment. If you require gas cooking, consult your local codes and a ventilation specialist. Some jurisdictions prohibit gas equipment in unvented spaces entirely.

Q:

Why do ventless systems work better with electric equipment?

A:

Electric cooking equipment produces only cooking effluent (grease, smoke, steam), while gas equipment also generates combustion byproducts including carbon monoxide, nitrogen dioxide, and water vapor. Ventless filtration systems can effectively capture cooking effluent through their multi-stage filters, but they cannot safely remove combustion gases as those require exhaust to outside air. This is why most jurisdictions prohibit gas equipment in spaces without external ventilation.

Shop Equipment

Ventless Cooking Equipment

Ventless Hood Systems

Warming & Holding Equipment

Related Guides & Resources

Additional Resources

Share This!